29
DRAIN PUMP REMOVAL INSTRUCTIONS
Drain Pump Removal Instructions:
1. Unplug the ice machine from the electrical supply and
remove the rear access cover from the ice machine.
(See page 26 for instructions).
2. Unscrew the leveling leg in the back corner until the
end of the threaded portion is ush with the threaded
nut insert in the base. (see Figure 43).
3. Unscrew the 3 hose clamps and remove the 3 hoses
from the front of the drain pump. (See Figure 43).
4. Rotate the drain pump and remove from the ice ma-
chine, (See Figure 42). It may be necessary to discon-
nect the ground wire connection in the back ange of
the cabinet. (See Figure 43).
5. Disconnect the ice machine power cord from the drain
pump (See Figure 44).
6. Drain the water in the drain pump’s reservoir by turn-
ing the pump upside down and allowing water to drain
through the pump’s inlet and vent tube ttings.
7. Installation of drain pump is reverse of this procedure.
Unscrew the leveling leg so
the end of the threads is ush
with the top of the nut insert.
Remove these 3 hose
clamps, then remove
the 3 tubes from the
drain pump
Drain pump ground
wire connection
Rotate drain pump and
remove from back of
ice machine.
Figure 42
Figure 43